{"dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": {"cveId": "CVE-2026-78308", "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b", "state": "PUBLISHED", "assignerShortName": "Deltaww", "dateReserved": "2026-08-24T08:32:54.873Z", "datePublished": "2026-09-24T08:35:58.944Z", "dateUpdated": "2026-09-24T12:36:20.452Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b", "shortName": "Deltaww", "dateUpdated": "2026-09-24T08:35:58.944Z"}, "title": "Authentication Bypass in DIAEnergie", "datePublic": "2026-09-24T08:01:00.000Z", "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "type": "CWE"}]}], "impacts": [{"capecId": "CAPEC-115", "descriptions": [{"lang": "en", "value": "CAPEC-115 Authentication Bypass"}]}], "affected": [{"vendor": "Deltaww", "product": "DIAEnergie", "versions": [{"status": "affected", "version": "0", "lessThan": "1.11.00.022", "versionType": "custom"}], "defaultStatus": "unaffected"}], "cpeApplicability": [{"operator": "OR", "nodes": [{"operator": "OR", "negate": false, "cpeMatch": [{"vulnerable": true, "criteria": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*", "versionStartIncluding": "0", "versionEndExcluding": "1.11.00.022"}]}]}], "descriptions": [{"lang": "en", "value": "Improper Authentication vulnerability in DIAEnergie allows Authentication Bypass.\n\nThis issue affects DIAEnergie: before 1.11.00.022.", "supportingMedia": [{"type": "text/html", "base64": false, "value": "&nbsp;Improper Authentication vulnerability in DIAEnergie allows Authentication Bypass.<p>This issue affects DIAEnergie: before 1.11.00.022.</p>"}]}], "references": [{"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00014_DIAEnergie%20Multiple%20Vulberabilities%20(CVE-2026-78308%20~%2078313).pdf"}], "metrics": [{"format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}], "cvssV3_1": {"version": "3.1", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseSeverity": "CRITICAL", "baseScore": 9.8, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"}}], "solutions": [{"lang": "en", "value": "Users are advised to contact Delta technical support to obtain and update to DIAEnergie v1.11.00.022 or a later version.", "supportingMedia": [{"type": "text/html", "base64": false, "value": "Users are advised to contact Delta technical support to obtain and update to DIAEnergie v1.11.00.022 or a later version.\n\n<br>"}]}], "credits": [{"lang": "en", "value": "Alex Williams from Pellera Technologies", "type": "finder"}, {"lang": "en", "value": "VulnCheck", "type": "coordinator"}], "source": {"discovery": "EXTERNAL"}, "x_generator": {"engine": "Vulnogram 0.2.0"}}, "adp": [{"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2026-09-24T12:36:13.592917Z", "id": "CVE-2026-78308", "options": [{"Exploitation": "none"}, {"Automatable": "yes"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-09-24T12:36:20.452Z"}}]}}