{"dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": {"cveId": "CVE-2026-82369", "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791", "state": "PUBLISHED", "assignerShortName": "brocade", "dateReserved": "2026-08-28T19:39:58.088Z", "datePublished": "2026-09-23T20:45:24.825Z", "dateUpdated": "2026-09-24T00:06:05.579Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "87b297d7-335e-4844-9551-11b97995a791", "shortName": "brocade", "dateUpdated": "2026-09-24T00:06:05.579Z"}, "title": "Insufficient input sanitization of shell metacharacters in Brocade SANnav before 3.0.1a", "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-78", "description": "CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')", "type": "CWE"}]}], "impacts": [{"capecId": "CAPEC-88", "descriptions": [{"lang": "en", "value": "CAPEC-88 OS Command Injection"}]}], "affected": [{"vendor": "Brocade", "product": "SANnav", "versions": [{"status": "affected", "version": "before 3.0.1a", "versionType": "SANnav"}], "defaultStatus": "unaffected"}], "descriptions": [{"lang": "en", "value": "Insufficient input sanitization of shell metacharacters in the Brocade SANnav CLI scripting component permits authenticated users to break out of restricted execution contexts on managed switches. An attacker with command execution permissions can leverage this flaw to run unauthorized shell commands across target fabric switches, bypassing command allow-lists and obtaining full administrative switch access. This vulnerability affects all Brocade SANnav versions before 3.0.1a.", "supportingMedia": [{"type": "text/html", "base64": false, "value": "<span>Insufficient input sanitization of shell metacharacters in the Brocade SANnav CLI scripting component permits authenticated users to break out of restricted execution contexts on managed switches. An attacker with command execution permissions can leverage this flaw to run unauthorized shell commands across target fabric switches, bypassing command allow-lists and obtaining full administrative switch access. This vulnerability affects all Brocade SANnav versions before 3.0.1a.</span>"}]}], "references": [{"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/38994"}], "metrics": [{"format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}], "cvssV4_0": {"attackVector": "ADJACENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "userInteraction": "NONE", "vulnConfidentialityImpact": "HIGH", "subConfidentialityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "subIntegrityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "version": "4.0", "baseSeverity": "HIGH", "baseScore": 8.6, "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"}}], "source": {"discovery": "INTERNAL"}, "x_generator": {"engine": "Vulnogram 1.0.5"}, "solutions": [{"lang": "en", "value": "Security update provided in Brocade SANnav 3.0.1a", "supportingMedia": [{"type": "text/html", "base64": false, "value": "<span>Security update provided in Brocade SANnav 3.0.1a</span>"}]}]}}}