{"dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": {"cveId": "CVE-2026-96606", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2026-09-23T13:58:48.048Z", "datePublished": "2026-09-23T22:15:09.319Z", "dateUpdated": "2026-09-23T22:15:09.319Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2026-09-23T22:15:09.319Z"}, "title": "LB-Link BL-CPE600EU Configuration Backup Mifi_config.bin information disclosure", "problemTypes": [{"descriptions": [{"type": "CWE", "cweId": "CWE-200", "lang": "en", "description": "Information Disclosure"}]}, {"descriptions": [{"type": "CWE", "cweId": "CWE-284", "lang": "en", "description": "Improper Access Controls"}]}], "affected": [{"vendor": "LB-Link", "product": "BL-CPE600EU", "versions": [{"version": "5.8.13", "status": "affected"}], "cpes": ["cpe:2.3:a:lb-link:bl-cpe600eu:*:*:*:*:*:*:*:*"], "modules": ["Configuration Backup Handler"]}], "descriptions": [{"lang": "en", "value": "A security flaw has been discovered in LB-Link BL-CPE600EU 5.8.13. This vulnerability affects unknown code of the file Mifi_config.bin of the component Configuration Backup Handler. The manipulation results in information disclosure. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."}], "metrics": [{"cvssV4_0": {"version": "4.0", "baseScore": 6.9, "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P", "baseSeverity": "MEDIUM"}}, {"cvssV3_1": {"version": "3.1", "baseScore": 5.3, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R", "baseSeverity": "MEDIUM"}}, {"cvssV3_0": {"version": "3.0", "baseScore": 5.3, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R", "baseSeverity": "MEDIUM"}}, {"cvssV2_0": {"version": "2.0", "baseScore": 5, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR"}}], "timeline": [{"time": "2026-09-23T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed"}, {"time": "2026-09-23T02:00:00.000Z", "lang": "en", "value": "VulDB entry created"}, {"time": "2026-09-23T16:03:52.000Z", "lang": "en", "value": "VulDB entry last update"}], "credits": [{"lang": "en", "value": "dakshana (VulDB User)", "type": "reporter"}, {"lang": "en", "value": "VulDB CNA Team", "type": "coordinator"}], "references": [{"url": "https://vuldb.com/vuln/408973", "name": "VDB-408973 | LB-Link BL-CPE600EU Configuration Backup Mifi_config.bin information disclosure", "tags": ["vdb-entry"]}, {"url": "https://vuldb.com/vuln/408973/cti", "name": "VDB-408973 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": ["signature", "permissions-required"]}, {"url": "https://vuldb.com/cve/CVE-2026-96606", "name": "CVE-2026-96606 | CVE Analysis and Report", "tags": ["third-party-advisory"]}, {"url": "https://vuldb.com/submit/901827", "name": "Submit #901827 | LB-Link CPE600EU V5.8.13  Information Disclosure", "tags": ["third-party-advisory"]}], "x_generator": ["VulDB PVTS v202609"]}}}