CVE-2024-7399
📛 CVE Title
CVE-2024-7399
Description
Improper limitation of a pathname to a restricted directory vulnerability in Samsung MagicINFO 9 Server version before 21.1050 allows attackers to write arbitrary file as system authority.
Overview
- State
- PUBLISHED
- Assigner (CNA)
- samsung.tv_appliance
- CVSS severity
- HIGH
- CVSS score
- 8.8 / 10
- CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H- Effective score
- 8.8 / 10 HIGH source: CNA overview
- CWE(s)
-
CWE-22,CWE-434 - Reserved
- 2024-08-02
- Published
- 2024-08-09 04:43 UTC
- Last updated
- 2026-04-25 03:55 UTC
- Source
- https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2024/7xxx/CVE-2024-7399.json
- Linked Threat
- CVE-2024-7399 — Samsung MagicINFO 9 Server: Samsung MagicINFO 9 Server Path Traversal Vulnerability
CISA Known Exploited Vulnerabilities CISA KEV
CISA has confirmed in-the-wild exploitation of this CVE. Federal agencies must remediate by the due date below; private orgs should treat it as priority-1.
- Vulnerability name
- Samsung MagicINFO 9 Server Path Traversal Vulnerability
- Vendor / project
- Samsung
- Product
- MagicINFO 9 Server
- Date added to KEV
- 2026-04-24
- Remediation due
- 2026-05-08
- Required action
- Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
- Ransomware campaign use
- Unknown
- CISA notes
- https://security.samsungtv.com/securityUpdates ; https://nvd.nist.gov/vuln/detail/CVE-2024-7399
- CISA listing
- www.cisa.gov/known-exploited-vulnerabilities-catalog
NVD triage scoring NVD CVE 2.0
Layer NVD adds on top of the CNA's CVE record — published / last-modified timestamps, exploitability / impact subscores, and the FIRST.org EPSS probability that this CVE will be exploited in the wild in the next 30 days.
- NVD published
- 2024-08-12 13:38:41 UTC
- NVD last modified
- 2026-04-24 20:23:57 UTC
- NVD CVSS v3.1
- 8.8 / 10 HIGH source: PSIRT@samsung.com
- NVD CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H- Exploitability subscore
- 2.8 / 10
- Impact subscore
- 5.9 / 10
- EPSS score
- 0.7071 (probability of exploitation in next 30 days)
- EPSS percentile
- 98.72% vs all CVEs — higher = more likely to be exploited, as of 2026-05-24
NVD / KEV / EPSS data refreshed 2026-05-25 00:55 UTC. Re-run the 🛰 Backfill from NVD button above to refresh.
European Union Vulnerability Database ENISA EUVD
ENISA's official EU repository for curated vulnerability intelligence. Carries a separate identifier (EUVD-YYYY-NNNN) and frequently exposes an earlier-published description + CVSS than NVD does.
- EUVD ID
-
EUVD-2024-48330 - Assigner
- samsung.tv_appliance
- Published
- Aug 9, 2024, 4:43:29 AM
- Updated
- Apr 25, 2026, 3:55:30 AM
- EUVD base score (CVSS 3.1)
-
8.8 / 10
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - EUVD-reported EPSS
- 70.7100
- Vendors
- Samsung Electronics
- Products
-
MagicINFO 9 Server (0 <21.1050)
- Aliases
-
GHSA-9x68-238r-w7mq
ENISA description: Improper limitation of a pathname to a restricted directory vulnerability in Samsung MagicINFO 9 Server version before 21.1050 allows attackers to write arbitrary file as system authority.
EUVD references (1)
Affected products (1)
| Vendor | Product | Versions | Platforms |
|---|---|---|---|
| Samsung Electronics | MagicINFO 9 Server |
0 (affected)
|
Windows |
Affected products — CPE 2.3 (1) NVD
NVD's normalized CPE 2.3 matchers, used by vendor tools (vulnerability scanners, asset managers) for automated detection. Compare with the CNA's free-text "Affected products" section above.
cpe:2.3:a:samsung:magicinfo_9_server:*:*:*:*:*:*:*:*
Vendor references (1)
References embedded in the original CVE record by the assigning CNA.
- https://security.samsungtv.com/securityUpdates vendor-advisory
MITRE references (1) cveawg.mitre.org
Pulled from MITRE's CVE Services API by the 🛰 Backfill from MITRE button.
- https://security.samsungtv.com/securityUpdates vendor-advisory
Web references (5)
DuckDuckGo results ranked by threat-intel / vendor advisory domains. Generated by the 🔎 Find references (web) button above — same flow as the Remediations search.
- http://cwe.mitre.org/data/definitions/22.html rapid7:cwe.mitre.org
- http://cwe.mitre.org/data/definitions/434.html rapid7:cwe.mitre.org
- https://attackerkb.com/topics/CVE-2024-7399 rapid7:attackerkb.com
- https://nvd.nist.gov/vuln/detail/CVE-2024-7399 rapid7:nvd.nist.gov
- https://www.cve.org/CVERecord?id=CVE-2024-7399 rapid7:www.cve.org
NVD-tagged references (3)
Reference list NVD curates from the CNA record, vendor advisories, and third-party reports. The tag chips below are NVD's analyst-assigned categories.
- https://arcticwolf.com/resources/blog-uk/arctic-wolf-observes-exploitation-of-path-traversal-vulnerability-in-samsung-magicinfo-9-server-cve-2024-7399/ 134c704f-9b21-4f2e-91b3-4a467353bcc0 Third Party Advisory
- https://security.samsungtv.com/securityUpdates PSIRT@samsung.com Vendor Advisory
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-7399 134c704f-9b21-4f2e-91b3-4a467353bcc0 US Government Resource
Indicators (3)
IOCs linked to the auto-promoted Threat row.
| Type | Value | VirusTotal | Attached |
|---|---|---|---|
| cwe |
CWE-22
|
no local data | 2026-05-14 02:58 UTC |
| cve |
CVE-2024-7399
|
no local data | 2026-05-14 02:58 UTC |
| cwe |
CWE-434
|
no local data | 2026-05-14 02:58 UTC |
Remediations (9)
Remediations are stored against the linked Threat row; the list below is deduplicated across both pages.
-
web:www.forbes.com
As security researchers warn about a dangerous Microsoft Windows update that isn't legitimate, users must pay close attention to what they are actually downloading.
2026-05-14 07:18 UTC -
web:learn.microsoft.com
Remediate security weaknesses discovered through security recommendations, and create exceptions if needed, in Defender Vulnerability Management.
2026-05-14 07:18 UTC -
web:portal.msrc.microsoft.com
The Security Update Guide provides information on the latest Microsoft security updates, helping users understand and address potential vulnerabilities effectively.
2026-05-14 07:18 UTC -
web:support.microsoft.com
Provides Windows client guidance for IT Pros to protect against speculative execution side-channel vulnerabilities.
2026-05-14 07:18 UTC -
web:www.bleepingcomputer.com
Today is Microsoft's January 2026 Patch Tuesday with security updates for 114 flaws, including one actively exploited and two publicly disclosed zero-day vulnerabilities.
2026-05-14 07:18 UTC -
web:cyberscoop.com
Threats Microsoft addresses 137 vulnerabilities in May's Patch Tuesday, including 13 rated critical The high volume of vulnerabilities reflects a growing trend researchers have been anticipating as artificial intelligence models are deployed to find previously uncovered defects in code.
2026-05-14 07:18 UTC -
web:www.csoonline.com
Microsoft has unveiled a new AI-driven vulnerability discovery system that identified 16 previously unknown Windows vulnerabilities, including four critical remote code execution flaws, in what ...
2026-05-14 07:18 UTC -
web:www.cve.org
At cve .org, we provide the authoritative reference method for publicly known information-security vulnerabilities and exposures
2026-05-14 07:18 UTC -
CISA KEV
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable. Due date: 2026-05-08 Known ransomware campaign use: Unknown
2026-05-14 01:13 UTC
AI Forensic Analysis
Only Available for Registered Users. Sign in to view.
Raw JSON
The full cvelistV5 record. Download as CVE-2024-7399.json.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7399",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-04-24",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-7399"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-25T03:55:30.861Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://arcticwolf.com/resources/blog-uk/arctic-wolf-observes-exploitation-of-path-traversal-vulnerability-in-samsung-magicinfo-9-server-cve-2024-7399/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-7399"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-24T00:00:00.000Z",
"value": "CVE-2024-7399 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "MagicINFO 9 Server",
"vendor": "Samsung Electronics",
"versions": [
{
"lessThan": "21.1050",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Anonymous working with Trend Mirco Zero Day Initiative"
}
],
"datePublic": "2024-08-08T23:09:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper limitation of a pathname to a restricted directory vulnerability in Samsung MagicINFO 9 Server version before 21.1050 allows attackers to write arbitrary file as system authority."
}
],
"value": "Improper limitation of a pathname to a restricted directory vulnerability in Samsung MagicINFO 9 Server version before 21.1050 allows attackers to write arbitrary file as system authority."
}
],
"impacts": [
{
"capecId": "CAPEC-650",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-650 Upload a Web Shell to a Web Server"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-09T04:43:29.828Z",
"orgId": "ca193ba2-0cff-4e34-b04e-1ea07103c6fe",
"shortName": "samsung.tv_appliance"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.samsungtv.com/securityUpdates"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca193ba2-0cff-4e34-b04e-1ea07103c6fe",
"assignerShortName": "samsung.tv_appliance",
"cveId": "CVE-2024-7399",
"datePublished": "2024-08-09T04:43:29.828Z",
"dateReserved": "2024-08-02T00:29:57.143Z",
"dateUpdated": "2026-04-25T03:55:30.861Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}