s2
--:--:--UTC

Searching APEX

Starting…

  1. Searching Threats, IOCs & Threat Intelligence locally
  2. Querying external providers
  3. Asking AI Forensic Validator
  4. Creating new entry from validated hit

0s elapsed

CVE-2026-82370

📛 CVE Title

Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service

Description

Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service permits network-adjacent attackers to execute arbitrary administrative switch CLI commands and issue container management instructions. This could allow an attacker to alter Fibre Channel fabric switch configurations or manipulate application container runtimes. This vulnerability affects Brocade SANnav versions before 3.0.1a.

Overview

State
PUBLISHED
Assigner (CNA)
brocade
CVSS severity
HIGH
CVSS score
CVSS 8.6 / 10 8.6 8.6 / 10
CVSS vector
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Effective score
8.6 / 10 HIGH source: CNA overview
CWE(s)
CWE-77
Reserved
2026-08-28
Published
2026-09-23 23:38 UTC
Last updated
2026-09-23 23:38 UTC
Source
https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/82xxx/CVE-2026-82370.json
Linked Threat
CVE-2026-82370 — Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service

NVD triage scoring NVD CVE 2.0

Layer NVD adds on top of the CNA's CVE record — published / last-modified timestamps, exploitability / impact subscores, and the FIRST.org EPSS probability that this CVE will be exploited in the wild in the next 30 days.

NVD published
2026-09-24 00:17:21 UTC
NVD last modified
2026-09-24 00:17:21 UTC

NVD / KEV / EPSS data refreshed 2026-09-24 04:34 UTC. Re-run the 🛰 Backfill from NVD button above to refresh.

Affected products (1)

VendorProductVersionsPlatforms
Brocade SANnav before 3.0.1a (affected)

Vendor references (1)

References embedded in the original CVE record by the assigning CNA.

Web references (0)

DuckDuckGo results ranked by threat-intel / vendor advisory domains. Generated by the 🔎 Find references (web) button above — same flow as the Remediations search.

No web references attached yet.

NVD-tagged references (1)

Reference list NVD curates from the CNA record, vendor advisories, and third-party reports. The tag chips below are NVD's analyst-assigned categories.

AI Forensic Analysis

Only Available for Registered Users. Sign in to view.

Raw JSON

The full cvelistV5 record. Download as CVE-2026-82370.json.

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before 3.0.1a",
              "versionType": "SANnav"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "<span>Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service permits network-adjacent attackers to execute arbitrary administrative switch CLI commands and issue container management instructions. This could allow an attacker to alter Fibre Channel fabric switch configurations or manipulate application container runtimes. This vulnerability affects Brocade SANnav versions before 3.0.1a.</span>"
            }
          ],
          "value": "Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service permits network-adjacent attackers to execute arbitrary administrative switch CLI commands and issue container management instructions. This could allow an attacker to alter Fibre Channel fabric switch configurations or manipulate application container runtimes. This vulnerability affects Brocade SANnav versions before 3.0.1a."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88: OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-23T23:38:48.095Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/38995"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Security update provided in Brocade SANnav 3.0.1a"
            }
          ],
          "value": "Security update provided in Brocade SANnav 3.0.1a"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2026-82370",
    "datePublished": "2026-09-23T23:38:48.095Z",
    "dateReserved": "2026-08-28T19:39:58.088Z",
    "dateUpdated": "2026-09-23T23:38:48.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}